Heating, Cooling, and Relative Humidity Thermostat, DIN Rail Mount
Model: DIN-THSTAT
Part #: 6509627
- Works with Crestron® remote temperature sensors (sold separately)
- Operates as part of a complete Crestron automation system (sold separately)
- Onboard controls for system setup and testing
- System integration via Cresnet® wired communications
- Cresnet powered (24VDC)
The DIN-THSTAT is a versatile heating, cooling and relative-humidity thermostat that provides control of radiant floor heat, forced air, and heat pump HVAC systems. DIN rail mounting allows for installation in an equipment cabinet, keeping the living area free from a wall-mounted thermostat. Small, unobtrusive remote temperature and humidity sensors1 gather the environmental conditions from the room and transmit the data to the DIN-THSTAT.
A Crestron control system connection allows temperature adjustments from virtually anywhere by using a Crestron touch screen, handheld remote, mobile app, or computer.
Remote Sensors
The CHV-RTS and CHV-RTHS (both sold separately) remote sensors provide indoor temperature and humidity data so that the DIN-THSTAT can be installed out of view. The CHV-RSS (sold separately) outdoor climate and floor temperature sensor enables outdoor low-temperature compensation to prevent condensation on windows during cold weather. The DIN-THSTAT accepts up to three temperature sensors. Each sensor connects via a single twisted pair wire.
Auxiliary Ports
Auxiliary ports allow state sensing from HVAC equipment and interfacing with additional HVAC devices.
DIN Rail Mounting
The DIN-THSTAT snaps onto a standard 35 mm DIN rail for installation in a wall mount enclosure (Crestron DIN-EN series or similar, sold separately) or on a wall panel. The DIN-THSTAT is designed to mount in a DIN-EN-2X18-HC-OPEN, DIN-EN-3X18-HC-OPEN, or DIN-EN-6X18-HC-OPEN for an attractive centralized mounting solution. The hinged cover provides easy access to equipment wiring while openings in the cover provide access to the DIN modules through the cover.
Cresnet ® Wired ommunications
The DIN-THSTAT communicates with a Crestron control system via the Cresnet control network. A pair of Cresnet ports is provided on the DIN-THSTAT to allow easy daisy-chaining of several DIN-THSTAT or Crestron DIN rail devices.
- Works with Crestron® remote temperature sensors (sold separately)
- Operates as part of a complete Crestron automation system (sold separately)
- Onboard controls for system setup and testing
- System integration via Cresnet® wired communications
- Cresnet powered (24VDC)
- Backlit LCD display
- Front panel controls for setup, temperature, and humidity adjustments
- 9M wide DIN rail mountable
- Warranty - Yes
- Spec Sheet available - Yes
- Certifications: FCC Part 15 Class B, IC Class B, CE
- Active Power: 3 Watt
- Current Draw: 1 Amps
- DC Voltage: 30 Volts
- Depth: 2.34 in
- Height: 3.68 in
- Width: 6.33 in
- Product Weight: 0.80 lbs
- AC Voltage: 24 Volts
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Measurement Range (Supplied by Remote Sensor) :
•Indoor Temperature: 32° to 110°F (0° to 43°C)
•Outdoor Temperature: -40° to 170°F (-40° to 77°C)
•Humidity: 0% to 100% RH - Temperature Tolerance: ±1ºF (±0.5ºC)
- Humidity Tolerance: ± 5.0% RH
- Setpoint Range: Auto: 38° to 99°F (3° to 37°C); Heat: 38° to 89°F (3° to 32°C); Cool: 59° to 99°F (15° to 37°C); Humidity: 5% to 90% RH
- COMMUNICATIONS:
•Cresnet® Wired: Control system integration or networking
•Keypad: (1) 5-way navigation pad; For menu navigation and temperature/humidity adjustments
•HOME: (1) pushbutton; Returns to the previous screen or the home screen
•BACK: (1) pushbutton; Steps menu back one level - Display:
•Type: RGB LCD
•Size: 1.80 in. (46 mm) diagonal
•Resolution: 176 x 220
•Function: Front panel display to view temperature and humidity settings; Used for local configuration - Connections:
•Y1, Y2, Y3: (1) Compressor stage 1, 2, and 3
•G: (1) Fan relay
•B: (1) Active in non-cool modes
•O: (1) Active in cool mode
•RC: (1) Reference cool
•RH: (1) Reference heat
•W1, W2, W3: (1) Heat stage 1, 2, and 3
•HUM: (1) Humidity call switch power
•AUX1, AUX2: (2) Output relay to interface with other HVAC devices
•AUX-IN: (1) Signal from HVAC state sensing or other custom programming
•TS1, TS2, G: (2) Remote sensor inputs and (2) ground inputs; For indoor remote temperature sensor (CHV-RTS), remote slab sensor (CHV-RSS), remote temperature and humidity sensors (CHV-RTHS), and 10k thermistors (all sensors and thermistors are sold separately); Each temperature sensor requires a dedicated low-capacitance twisted pair wire (<7 nF per run) and supports a wire length of 500 ft (152 m) using CAT5. Thermostat wire is not recommended, but may be used if necessary at lengths up to 100 ft (30 m).
•TS3, G: (1) From outdoor remote temperature sensor and (1) ground; Also compatible with 10k thermistors. All sensors and thermistors are sold separately. (1) Remote sensor input and (1) ground input; For outdoor remote slab sensor (CHV-RSS) and 10k thermistors sensors and thermistors are sold separately); Each temperature sensor requires a dedicated low-capacitance twisted pair wire (<7 nF per run) and supports a wire length of 500 ft (152 m) using CAT5. Thermostat wire is not recommended, but may be used if necessary at lengths up to 100 ft (30 m).
•24 Y Z G: (2) 4-pin detachable terminal blocks; Cresnet secondary port with hardwire parallel pass-through
•USB: (1) Micro B female, USB 2.0 computer console port for firmware download
•INTERFACE: For future use - Humidity: 10% to 90% RH (noncondensing)
- Heat Dissipation: 10 BTU/hr maximum; For indoor use only
- Housing: Plastic
- Mounting: 35 mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45 mm front panel cutout, occupies 9 DIN module spaces (162 mm)
Create Spaces
623 S Americana Blvd, Boise, ID 83702
Boise, ID 83702
USA
2083850507