8-outlet Energy Monitoring Power Conditioner and Controller 200
Model: PC-200
Part #: 6507243
- Rack-mountable power conditioner and controller
- Eight switched rear panel outlets, arranged in banks of two
- Adjustable turn-on delay and remote switching per each of three banks
- One unswitched front panel outlet
- Built-in current sensing and energy monitoring
A rack-mountable 15A, 120V AC power controller, conditioner, and surge protector for professionally installed AV and IT systems. It provides switching of three separate outlet banks, plus energy monitoring of all connected devices. Features network connectivity, web browser setup, event logging, ping monitoring, temperature sensing, and UL 1449 compliance.
The PC-200 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are arranged in four banks of two, three of which are turn-on delay-adjustable when controlled from the front panel power switch. The same three outlet banks are also individually controllable via a control system to enable selective switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.
Built-in RMS voltage and current monitoring enables logging and reporting of the line voltage, current, power, and energy usage at the input. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.
Power Conditioning
A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. ...
- Rack-mountable power conditioner and controller
- Eight switched rear panel outlets, arranged in banks of two
- Adjustable turn-on delay and remote switching per each of three banks
- One unswitched front panel outlet
- Built-in current sensing and energy monitoring
- Line voltage monitoring
- Professional grade surge protection
- UL® 1449 Type 3 Listed
- Thermal breaker overload protection
- Adjustable over-voltage and under-voltage cut-off
- EMI and RFI noise filtering
- Wiring fault detection
- Ambient temperature sensing and over-temperature cut-off
- Ping monitoring (device lockup detection and reboot)
- Built-in energy usage and event logging
- Front panel main power switch and status indicators
- Easy setup and operation via web browser
- Crestron® control system integration via Ethernet or Cresnet®
- Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP
- Single-space 19 inch rack-mountable
- Rated 15 Amps at 120 Volts AC
- UL Rated - Yes
- Warranty - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 113 F
- Operating Temperature (Minimum): 32 F
- Number of Outlets: 8
- AC Voltage: 120 Volts
- Current Draw: 15 Amps
- Depth: 10.56 in
- Height: 1.73 in
- Width: 19 in
- Product Weight: 8.20 lbs
- Warranty (Length/Type): 5 Years Limited
- Power Conditioner and Controller:
•Maximum Output Current, Total: 15 Amps at 120 Volts AC
•Maximum Output Current, Per Outlet/Bank: 15 Amps at 120 Volts AC (subject to a maximum total output current of 15 Amps for all outlets combined)
•Filtration: 40 dB at 100 kHz, 50 dB at 300 kHz, with 50 Ohm load
•Surge Protection Modes: L-G, L-N, N-G
•Surge Protection Shutoff: Shuts off rear outlets if surge protection is compromised
•Energy Dissipation: 2000 Joules per Mode
•Clamping Voltage: 370 Volts
•Clamping Time: 1 ns
•Wiring Fault Detection: Shuts off rear outlets if a wiring fault is detected at the input [3]
•Voltage Sensing Range: 90.0 to 160.0 Volts rms +/-1%, measured at input
•Current Sensing Range: 0.4 to 15.0 Amps rms +/-1% (resistive), measured at input
•Ambient Temperature Sensing Range: -13.0° to 221.0° +/-4° F (-25.0° to 105.0° +/-2° C)
•Under Voltage Cutoff: Adjustable 90 to 110 Volts, shuts off rear outlets if input drops below set value
•Over Voltage Cutoff: Adjustable 130 to 147 Volts, shuts off rear outlets if input exceeds set value
•Over Temperature Cutoff: Adjustable -13.0° to 221.0° F (-25.0° to 105.0° C), shuts off rear outlets if input exceeds set value
•Turn-On Delay Adjustment: 0.1 to 10.0 seconds, adjustable per each of rear outlet banks "DELAYED ON 1 - 3" - COMMUNICATIONS:
•Ethernet: 10/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full/half duplex, TCP/IP, UDP/IP, CIP, DHCP, SSL, TLS, SNMP, Web Server, SMTP e-mail client, web browser setup and control, Crestron control system integration, Crestron Fusion Cloud monitoring, MyCrestron.com monitoring [2]
•Cresnet: Cresnet slave mode - Connectors:
•120V~ 15A 60Hz: (1) Attached 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug
•Line power input
•SWITCHED ON 1: (2) NEMA 5-15R AC power outlets
•Locally switched 120 Volt AC power outlet bank
•DELAYED ON 1 - 3: (6) NEMA 5-15R AC power outlets
•Comprises three banks of two switched 120 Volt AC power outlets
•Locally switched with adjustable turn-on delay per bank
•Remote switchable per bank
•TEMP: (1) 2-pin 3.5 mm detachable terminal block
•Connection for external temperature sensor (included)
•Y, Z, G: (1) 3-pin 3.5 mm detachable terminal block
•Cresnet slave port
•LAN: (1) 8-pin RJ45 jack
•10Base-T/100Base-TX Ethernet port
•G: (1) 6-32 screw
•Chassis ground lug
•ALWAYS ON (front): (1) NEMA 5-15R AC power outlet
•Unswitched 120 Volt AC power outlet - Controls and Indicators:
•PWR: (1) Bi-color green/amber LED, indicates line power is present, illuminates amber when the power switch is off and while booting, illuminates green when the power switch is on and the unit is operating normally, turns amber if the rear outlets have been shut off due to a fault condition
•FAULT: (1) Red LED, indicates any of the following fault conditions: surge protection is compromised, line and neutral are reversed, or no ground is detected [3]
•PROTECT: (1) Green LED, indicates surge protection is fully functional
•SHUTDOWN: (1) Amber LED, indicates power to the rear outlets is shut off due to an over-voltage, under-voltage, over-temperature, line input miswire, missing ground, or compromised surge protection fault condition
•HW-R: (1) Recessed pushbutton, initiates a hardware reset of the internal CPU (does not affect outlets)
•SETUP: (1) Recessed pushbutton & red LED, for touch-settable ID (TSID) and Ethernet autodiscovery
•Power Switch: (1) Rocker switch, "On" position initiates turn-on delay sequence to the rear panel outlets, "Off" position turns all rear outlets off immediately
•THERMAL BREAKER (rear): Disrupts power to all outlets in case of an overload condition, press to reset after overload condition is resolved
•LAN (rear): (2) LEDs, green LED indicates Ethernet link status, amber LED indicates Ethernet activity - Environmental:
•Humidity: 10% to 90% RH (non-condensing) - Construction:
•Chassis: Steel, black finish
•Front Panel: Extruded aluminum, black finish, polycarbonate label overlay
•Mounting: 1 RU 19-inch rack-mountable (rack ears included)
•Temperature Sensor: Adhesive or magnetic mount, 9.8 ft (3.0 m) attached lead - Notes::
•1. Crestron control system and custom programming sold separately.
•2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.
•3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-200 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-200 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.
Create Spaces
623 S Americana Blvd, Boise, ID 83702
Boise, ID 83702
USA
2083850507
https://createspaces.com/