Zum Wired J-Box Load Controller, Switching, 20A, 100-277V with Link Communication
Model: ZUMLINK-JBOX-20A-SW
- Zum® wired junction box-mounted lighting load plug load controller
- Integration with Zum keypads, occupancy sensors, vacancy sensors, and daylight sensors (sold separately)
- Zero cross switch control of 20A, 100-277V
- Supports in-room device daisy chaining
- Integrated contact closure input
The Crestron Zum® Wired ZUMLINK-JBOX-20A-SW provides zero cross switching for high inrush lighting control. The device can be wired to other in-room Zum devices to provide load control. Energy-saving options are available to enable daylighting, occupancy or vacancy sensing, and centralized monitoring and management.
Zum Link Wired Technology
Zum Link technology allows for in-room lighting control through compatible keypads and sensors. Two RJ-45 ports on the device allow for connection to a Zum Net device and for in-room device daisy-chaining. Similar to the Zum Wireless system, Zum Link devices work together in a local ecosystem to provide customized solutions as needed.
Easy Installation
For flexibility and ease-of-use, Zum load controllers are installed in a room with Zum keypads, occupancy or vacancy sensors, and/or a daylight sensor for complete commercial lighting control. Finish the installation by quickly commissioning the room through the Zum app.
Override Contact Closure Input
An integrated contact closure input or relay output on the ZUMLINK-JBOX-20A-SW provides the means to place all connected Zum Net and Zum Link devices into Emergency Override mode.
- Zum® wired junction box-mounted lighting load plug load controller
- Integration with Zum keypads, occupancy sensors, vacancy sensors, and daylight sensors (sold separately)
- Zero cross switch control of 20A, 100-277V
- Supports in-room device daisy chaining
- Integrated contact closure input
- Flying lead wiring connections
- Knockout mount to a standard 4 in. square junction box
- Spec Sheet available - Yes
- Certifications: IC, FCC, cUL, UL
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- AC Voltage (Minimum): 100 Volts
- AC Voltage (Maximum): 277 Volts
- Current Draw: 20 Amps
- Depth: 2.03 in
- Height: 4.83 in
- Width: 4.25 in
- Product Weight: 0.44 lbs
- Load Control:
•Switch Load Types: LED, electronic ballasts, incandescent, magnetic low-voltage, electronic lowvoltage,neon/cold cathode, high-intensity discharge, small motor loads
•Load Rating: 20A 100-277VAC, 50/60 Hz high inrush, zero cross switching; 0.5 HP at 120-277VAC
•Short Circuit Protection: 40A non-replaceable fuse - Wired Communications:
•ZUMLINK (ROOM): (2) RJ-45 ports; In-room Zum Link device daisy-chaining; 85mA power available for Zum Link devices, including ZUMLINK-KP keypads
•24V, OCC, GND: Occupancy sensor input; 85mA available output current; Spring clamp connector
•24V, PHO, GND: Photo sensor input; Spring clamp connector
•OVR, GND: Override control input; Spring clamp connector - Controls and Indicators:
•TEST: (1) Pushbutton and (1) green LED; Push to toggle the switched load output on and off; Press and hold to cycle the dimming level up and down; LED indicates that the load is turned on; LED lights and flashes during room setup and factory reset
•ZUMLINK Status: (1) bi-color green/red LED; LED lights green in normal operation; LED lights red when a fault is detected - Connections:
•Hot: (1) 14 AWG Class 1 flying lead; Black, line power input
•Neutral: (1) 14 AWG Class 1 flying lead; White, neutral
•Red: (1) 14 AWG Class 1 flying lead, red, AC output
•Switched Load: (1) 14 AWG Class 1 flying lead;Red, switched load output - Humidity: 10% to 90% RH (noncondensing)
- Construction:
•Housing: Plastic, white, UL 94 5VA flame rated
•Mounting: Mounts to the side of a 4 in. square junction box via a 1/2 in. conduit knockout; Meets the requirements of UL 2043 for installation in an environmental air-handling (plenum) space
Create Spaces
623 S Americana Blvd, Boise, ID 83702
Boise, ID 83702
USA
2083850507