Pro AV Catalog
 
Request Quote
All Products

125V/15A Tamper Resistant Self-testing GFCI Receptacle, Black

Model: NTR-15-GFST-BL

  • Continuous self-test functionality disconnects power to receptacle if critical components are damaged and GFCI protection is lost providing “continuous self-testing”
  • Initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less
  • Three provisions for providing protection:
  • Continuous electronic sensing, testing and evaluation utilizing diagnostic software located on the printed circuit board.
  • Traditional testing mode by manually operating the “test and reset” buttons utilizing a supervisory circuit as specified in UL 943 section 5.15.
Compare
Project List
Product Info
Tech Specs
Documents
Other Options
NTR-15-GFST is a 125V/15A tamper resistant, self-testing GFCI receptacle. Continuously self-test functionality disconnects power to receptacle if critical components are damaged and GFCI protection is lost providing “continuous self-testing” that initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less.
  • Continuous self-test functionality disconnects power to receptacle if critical components are damaged and GFCI protection is lost providing “continuous self-testing”
  • Initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less
  • Three provisions for providing protection:
    • Continuous electronic sensing, testing and evaluation utilizing diagnostic software located on the printed circuit board.
    • Traditional testing mode by manually operating the “test and reset” buttons utilizing a supervisory circuit as specified in UL 943 section 5.15.
    • Auto-sensing mode for immediate interruption for a ground fault condition for Class A protection (4-6 mA)
  • Manual Test-this design incorporates a full system test function
  • The GFCI, when manually tested, induces a simulated ground fault leakage current to the printed circuit board
  • This in turn causes the mechanical system to react based on the action of the solenoid. The entire mechanical and electronic GFCI system is reviewed for functionality
  • Reverse wire safety feature-if wired incorrectly there will be no power to the face or to downstream receptacles for added safety
  • Clear visual indication of GFCI status
    LED indicating lights:
    • Green LED (power to the device)
    • Red LED (trip condition/ground fault condition)
    • Flashing Red LED (end of life)
  • Permanently installed internal tamper-resistant shutter mechanism capable of resisting insertion of foreign elements into the device
  • Internal back wiring clamp and guide pocket quick and dependable termination
  • Receptacle face compatible with NEMA designer and NovaT® designer-opening wallplates
  • Compliant with NEC® 406.12 and NEC® 517-18(c)
  • Available in black
 
Request Quote
 

Suggested Products

Shopping Basket