SmartOnline 120V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial
Series: SMARTONLINEâ„¢
Model: SU3000RTXL3U
- SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
- True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions
- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
- Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Product Info
Tech Specs
Related Products
Documents
3000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor with an installed depth of 26 inches. Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT-3U (multi-pack compatible) external battery packs. Full time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA 5-15, NEMA 5-15/20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITHD 2-post rackmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. $250,000 connected equipment insurance.
- SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
- True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions
- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
- Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values
- Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)
- Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT-3U (no limit) external battery packs
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches
- Ships with all mounting accessories for 4 post rackmount installation
- Optional 2POSTRMKITHD enables 2 post rackmount installation (not wallmount compatible)
- Optional 2-9USTAND accessory enables small-footprint upright tower placement
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and r
- Built-in Emergency Power Off (EPO) interface with cable
- NEMA L5-30P input plug; NEMA 5-15/20R & L5-30R output receptacles
- Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has four outlets)
- Front panel LEDs offer current monitoring and battery charge level information
- UPS ships fully assembled in full compliance with DOT regulations; no time consuming connection of internal batteries by user required
- Single line TEL/DSL or network ethernet line surge suppression
- $250,000 Ultimate Lifetime Insurance
- Package Includes SU3000RTXL3U UPS System, PowerAlert Software and Cabling, Mounting hardware for 4 post rack enclosures, Instruction manual
- Warranty - Yes
- Rackmountable - Yes
- UL Rated - Yes
- Spec Sheet available - Yes
- Cord Length (in/mm): 120 in
- UL Rated: Yes
- DC Voltage: 72 Volts
- Depth: 26 in
- Height: 5.20 in
- Width: 17.80 in
- Product Weight: 73.80 lbs
- Shipping Weight: 112.40 lbs
- Warranty (Length/Type): 2 Years
- Output volt amp capacity: 3000 VA
- Output Watt Capacity: 2400
- Output power factor: 0.8
- Crest Factor: 3:1
- Nominal Output Voltage(s) Supported: 110V; 120V
- Nominal Voltage details: 120 V default
- Frequency Compatibility: 50 / 60 Hz
- Frequency compatibility details: Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
- Output voltage regulation (line mode): +/- 2%
- Output voltage regulation (Economy line mode): +/- 10%
- Output voltage regulation (Battery mode): +/- 2%
- Built-in UPS output receptacles: 4 5-15R outlet(s); 4 5-15/20R outlet(s); 1 L5-30R outlet(s)
- Built-in controllable switched load banks: Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets)
- Output circuit breaker: 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered
- Output AC waveform (AC mode): Sine wave
- Output AC waveform (battery mode): Pure Sine wave
- Rated input current (at maximum load): 24A
- Nominal Input Voltage(s) Supported: 110V AC; 120V AC
- UPS input connection type: L5-30P
- Recommended Electrical Service: 30A 120V
- Full Load Runtime: 5 min. (2400w)
- Half Load Runtime: 14 min. (1200w)
- Battery recharge rate (included batteries): Less than 6 hours from 10% to 80%
- Voltage regulation description: Online, double-conversion power conditioning
- Overvoltage correction: 2% output voltage regulation during overvoltages to 150
- Undervoltage correction: 2% output voltage regulation during undervoltages to 80
- Severe undervoltage correction: 2% output voltage regulation during undervoltages to 65 (under 70% load only)
- Rack Units (Height): 3U
- UPS Shipping dimensions (height x width x depth): 11.2 x 23 x 31.5 inch
- UPS housing material: Steel
- Cooling Method: Fan
- Storage Temperature Range: -15 to +50 °C
- Relative Humidity: 0 to 95%, non-condensing
- AC mode BTU / hr. (full load): 1112.7
- AC economy mode BTU / hr. (full load): 520.9
- Battery mode BTU / hr. (full load): 1219.3
- AC economy mode efficiency rating (100% load): 0.94
- Low voltage transfer to battery power (setpoint): 80V (100% load), 65V ( <70% load)
- High voltage transfer to battery power (setpoint): 150
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
- RoHS: Yes
- CISCO: Yes
- Rackmountable: Yes
On-Line Double-Conversion UPS
124 kb
- Data Sheet
Request Quote
Suggested Products
Thank you!
Someone will be in touch with you shortly.
Contact Create Spaces
close
Create Spaces
623 S Americana Blvd, Boise, ID 83702
Boise, ID 83702
USA
2083850507
https://createspaces.com/
Contact in regards to this product:
Tripp Lite
Model: SU3000RTXL3U
Request more information from a dealer near you
close
Request more information from a dealer near you