4-channel 120V High-inrush Switch Dimmer Module with Terminal Block, 4 Feeds
Model: GL-CAEN-4HSW4 KIT
Part #: 6508535
- Four-channel high-inrush switch module for commercial lighting applications
- Installs in a Crestron® CAEN or CAEN-MLO enclosure
- Supports on/off switching of LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, and high-intensity discharge lighting loads
- Also supports on/off switching of 1/2 HP motor loads
- Individual feed inputs per channel
Provides four channels of switching for commercial lighting applications. Supports a full range of high-inrush, non-dimmable lighting loads. Installs in a CAEN or CAEN-MLO wall mount automation enclosure as part of a complete Crestron® centralized lighting control system.
The Crestron® GL-CAEN-4HSW4 is a four-channel, four-feed switch module designed for 120V commercial lighting system applications. It installs in a CAEN or CAEN-MLO enclosure and provides control of non-dimmable lighting loads including LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, and high-intensity discharge. It can also be used to switch motor loads. Individual feed capability provides four independent single-channel switches in one module space. Each channel is rated for 16 Amps, with a total module rating of 64 Amps when fed from four separate 20 Amp feeds.
Air-Gap Relays
An air-gap relay on each channel output allows individual circuits to be serviced without disabling the entire module.Â
Silent Operation
Low-maintenance convection cooling with over-sized heatsinks affords silent operation with no mechanical components to wear out.
Emergency Lighting Control
The GL-CAEN-4HSW4 is UL® 924 and CSA® C22.2 No. 141-15 listed for use in controlling emergency lighting loads. In the event of a power failure, a contact closure from a power loss sensor (Crestron GLS-PLS-120/277, sold separately) activates the override mode in the GL-CAEN-4HSW4 to turn on each designated lighting load if it is off (assuming line power is supplied by a backup power source).
Centralized Lighting Cabinet Installation
Crestron GL-CAEN series commercial lighting control modules are designed to be installed in a CAEN or CAEN-MLO wall mount enclosure. Available in a variety of sizes, CAEN and CAEN-MLO enclosures provide a scalable, high-density centralized lighting control solution for any-sized commercial building or facility. A selection of GL-CAEN module types is offered to accommodate a wide range of load types and system configurations.
Each lighting control module, including the GL-CAEN-4HSW4, ships complete with a DIN rail terminal block for termination of the high-voltage feed and load wiring. This terminal block mounts beside the module within the enclosure.
- Four-channel high-inrush switch module for commercial lighting applications
- Installs in a Crestron® CAEN or CAEN-MLO enclosure
- Supports on/off switching of LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, and high-intensity discharge lighting loads
- Also supports on/off switching of 1/2 HP motor loads
- Individual feed inputs per channel
- Rated 16 Amps per channel, 64 Amps total (using four 20 Amp feeds), at 120 Volts AC
- Built-in air gap relay per channel
- Convection cooled for silent operation
- Closure-activated override mode
- UL® 924 and CSA® C22.2 No. 141-15 listed for emergency lighting control
- Crestron system integration via Cresnet®
- Includes terminal block for high-voltage wiring
- CEC Title 24 2013 compliant
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Certifications: CE, UL, FCC
- AC Voltage: 120 Volts
- Depth: 3.43 in
- Height: 7.59 in
- Width: 6.92 in
- Product Weight: 3 lbs
- Load Control:
•Switch Channels: 4
•Switched Load Types: LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, high-intensity discharge (HID), motor
•Per Channel Load Rating: 16 Amps, 1/2 HP
•Module Total Load Rating: 64 Amps
•Line/Load Voltage: 120 Volts AC, 50/60Hz, requires up to four single-phase feeds (may be same or different phases) - Connections :
•Via Terminal Block (included):
•LINE 1 - 4: (4) Screw terminals, black, line power feed inputs (per channel)
•SW 1 - 4: (4) Screw terminals, red, switched load outputs (per channel)
•N IN 1 - 4: (4) Screw terminals, white, line power feed neutrals (per channel)
•N OUT 1 - 4: (4) Screw terminals, white, load neutrals (per channel)
•Note: Each terminal accepts one 14-10 AWG wire
•Module Interconnect: (2) 5-pin 0.156 inch headers
•Cresnet/Override interconnect ports
•Each connects to the adjacent module using the interconnect jumper provided
•Connects to a CAEN-BLOCK (sold separately) when installed in the lowest position within the enclosure - Controls and Indicators:
•PWR: (1) Green LED, indicates line power is applied to the LINE 1 terminal
•NET: (1) Yellow LED, indicates Cresnet communication with the control system
•SETUP: (1) Pushbutton and (1) red LED, used to enter Local mode and test each channel
•1 - 4: (4) Red LEDs, each indicates the status of the corresponding channel - Environmental:
•Humidity: 10% to 90% RH (non-condensing)
•Heat Dissipation: 16 BTU/hr + (0.41 BTU/hr x Load Current in Amps), 42 BTU/hr at maximum load - Enclosure:
•Gray metal with black heat sink, surface mount module with (2) integral mounting flanges
•Occupies 1 module space in a CAEN or CAEN-MLO enclosure
Create Spaces
623 S Americana Blvd, Boise, ID 83702
Boise, ID 83702
USA
2083850507